Indoor temperature sensor error
MEDIUMRoom temperature sensor fault. Check sensor connections and replace if necessary.
Action Required: Schedule service within 1-2 days
E2
Indoor coil sensor error
MEDIUMEvaporator coil temperature sensor malfunction. Professional sensor replacement required.
Action Required: Schedule service within 1-2 days
E3
Outdoor coil sensor error
MEDIUMCondenser coil temperature sensor fault. Replace outdoor coil sensor.
Action Required: Schedule service within 1-2 days
E4
Outdoor temperature sensor error
MEDIUMAmbient temperature sensor malfunction. Check outdoor sensor wiring.
Action Required: Schedule service within 1-2 days
E5
Communication error
URGENTIndoor/outdoor unit communication failure. Inspect control cable connections.
Action Required: Contact professional technician immediately
E6
Indoor fan motor error
URGENTIndoor fan motor malfunction. Check motor operation and speed feedback.
Action Required: Contact professional technician immediately
E7
Outdoor fan motor error
URGENTOutdoor fan motor fault. Inspect fan motor and electrical connections.
Action Required: Contact professional technician immediately
E8
Discharge temperature error
MEDIUMCompressor discharge temperature abnormal. Professional diagnosis required.
Action Required: Schedule service within 1-2 days
E9
Suction temperature error
MEDIUMCompressor suction temperature abnormal. Check refrigerant system.
Action Required: Schedule service within 1-2 days
E10
PCB communication error
URGENTControl board communication fault. Check board connections.
Action Required: Contact professional technician immediately
E11
Water level sensor error
MEDIUMCondensate water level sensor fault. Check drainage system.
Action Required: Schedule service within 1-2 days
E12
Filter sensor error
LOWAir filter sensor malfunction. Check filter and sensor.
Action Required: Monitor and perform basic maintenance
E13
Remote sensor error
LOWRemote controller sensor fault. Check controller and connections.
Action Required: Monitor and perform basic maintenance
E14
Humidity sensor error
MEDIUMHumidity sensor malfunction. Check sensor and connections.
Action Required: Schedule service within 1-2 days
E15
Position sensor error
MEDIUMMotor position sensor fault. Professional sensor replacement required.
Action Required: Schedule service within 1-2 days
C1
Compressor drive error
URGENTCompressor drive circuit malfunction. Professional diagnosis required.
Action Required: Contact professional technician immediately
C2
Compressor protection
URGENTCompressor protection activated. Check electrical supply and refrigerant.
Action Required: Contact professional technician immediately
C3
Current sensor error
MEDIUMCurrent sensor malfunction. Professional sensor replacement needed.
Action Required: Schedule service within 1-2 days
C4
Voltage sensor error
MEDIUMVoltage sensor fault. Check electrical connections and sensor.
Action Required: Schedule service within 1-2 days
C5
Inverter communication error
URGENTInverter control communication fault. Professional inverter diagnosis required.
Action Required: Contact professional technician immediately
C6
Control board error
URGENTMain control board malfunction. Professional board replacement required.
Action Required: Contact professional technician immediately
C7
Configuration error
MEDIUMSystem configuration error. Check system settings and parameters.
Action Required: Schedule service within 1-2 days
C8
Calibration error
MEDIUMSystem calibration error. Professional recalibration required.
Action Required: Schedule service within 1-2 days
C9
Control sequence error
MEDIUMControl sequence malfunction. Professional diagnosis required.
Action Required: Schedule service within 1-2 days
C10
Control valve error
URGENTElectronic control valve malfunction. Professional valve replacement needed.
Action Required: Contact professional technician immediately
F1
High pressure protection
URGENTHigh pressure switch activated. Check refrigerant charge and system restrictions.
Action Required: Contact professional technician immediately
F2
Low pressure protection
URGENTLow pressure protection activated. Check for refrigerant leaks and insufficient charge.
Action Required: Contact professional technician immediately
F3
Freeze protection
MEDIUMIndoor coil freeze protection activated. Check airflow and refrigerant levels.
Action Required: Schedule service within 1-2 days
F4
Four-way valve error
URGENTReversing valve malfunction. Professional valve inspection and replacement needed.
Action Required: Contact professional technician immediately
Air filter severely clogged. Clean or replace air filters immediately.
Action Required: Monitor and perform basic maintenance
Fan speed control fault. Check fan motor and control electronics.
Action Required: Schedule service within 1-2 days
F7
Float switch error
MEDIUMCondensate overflow protection activated. Check drain system.
Action Required: Schedule service within 1-2 days
Defrost cycle malfunction. Check defrost sensors and control.
Action Required: Schedule service within 1-2 days
F9
Fresh air damper error
LOWFresh air damper control fault. Check damper motor and position.
Action Required: Monitor and perform basic maintenance
F10
Flow control error
MEDIUMRefrigerant flow control malfunction. Check expansion valve operation.
Action Required: Schedule service within 1-2 days
H1
Compressor overheat
URGENTCompressor overheating protection. Check refrigerant levels and electrical supply.
Action Required: Contact professional technician immediately
H2
Inverter overheat
URGENTInverter circuit overheating. Check ventilation and component condition.
Action Required: Contact professional technician immediately
H3
High voltage protection
MEDIUMSupply voltage too high. Check electrical supply and voltage regulation.
Action Required: Schedule service within 1-2 days
H4
High current protection
URGENTElectrical current too high. Check wiring and electrical connections.
Action Required: Contact professional technician immediately
H5
High temperature alarm
URGENTSystem temperature too high. Check system operation and ventilation.
Action Required: Contact professional technician immediately